Logo do repositório
  • Página Inicial(current)
  • Buscar
    Por Data de PublicaçãoPor AutorPor TítuloPor Assunto
  • Tutoriais
  • Documentos
  • Sobre o RI
  • Eventos
    Repositório Institucional da UFRN: 15 anos de conexão com o conhecimento
  • Padrão
  • Amarelo
  • Azul
  • Verde
  • English
  • Português do Brasil
Entrar

SIGAA

  1. Início
  2. Pesquisar por Autor

Navegando por Autor "Augusto, Elaine Moura"

Filtrar resultados informando as primeiras letras
Agora exibindo 1 - 1 de 1
  • Resultados por página
  • Opções de Ordenação
  • Nenhuma Miniatura disponível
    Artigo
    Development of immunoassays for anti-electronegative LDL autoantibodies and immune complexes
    (Clinica Chimica Acta, 2012-01) Evangelista, Karine Cavalcanti Maurício Sena; Faulin, Tanize do Espirito Santo; Pacheco, Débora Bezerra; Augusto, Elaine Moura; Abdalla, Dulcineia Saes Parra
    Background: Electronegative low-density lipoprotein (LDL−) promotes atherosclerosis through inflammatory and immunologic mechanisms that lead to the production of anti-LDL(−) autoantibodies and to the subsequent formation of immune complexes (IC) and macrophage foam cells. We described the development and validation of an ELISA for the quantification of free anti-LDL(−) autoantibodies and an ELISA for the quantification of IC consisting of LDL(−)-bound IgG in human plasma. Methods: LDL(−) purified from human plasma, and anti-LDL(−) monoclonal antibody Fab fragments were adsorbed onto ELISA plates to capture anti-LDL(−) autoantibodies and IC-LDL(−), respectively. The performance characteristics of both ELISAs, including the limits of detection and quantification, accuracy and interand intra-assay precision were evaluated. Linearity, interference and stability tests were also performed. Results: The calibration range of the anti-LDL(−) assay was 0.004–0.125 mU/l and plasma demonstrated a dilutional linearity when diluted 1:100, 1:200, 1:400 and 1:800. The calibration range of the IC-LDL(−) assay was 0.06–4 U/l, and plasma demonstrated a dilutional linearity when diluted 1:12.5, 1:25, 1:50 and 1:100. Both ELISAs showed intra- and inter-assay precision and recovery within the required limits for immunoassays. Conclusion: These ELISAs can be used in clinical studies and for the biochemical investigation of atherosclerosis. In addition, they will enable the comprehensive evaluation of the importance of bound or free autoantibodies against LDL(−) in this disease
Repositório Institucional - UFRN Campus Universitário Lagoa NovaCEP 59078-970 Caixa postal 1524 Natal/RN - BrasilUniversidade Federal do Rio Grande do Norte© Copyright 2025. Todos os direitos reservados.
Contato+55 (84) 3342-2260 - R232Setor de Repositórios Digitaisrepositorio@bczm.ufrn.br
DSpaceIBICT
OasisBR
LAReferencia
Customizado pela CAT - BCZM